CABLE ANDREW RG 8 USA






ANDREW RG 8


Construction Materials
Jacket ColorBlack
Jacket MaterialNon-halogenated PE
Braid MaterialTinned copper
Shield Tape MaterialAluminum
Dielectric MaterialFoam PE
Inner Conductor MaterialCopper-clad aluminum wire

Dimensions
Cable Length300 m | 984 ft
Diameter Over Dielectric7.240 mm | 0.285 in
Diameter Over Jacket10.290 mm | 0.405 in
Inner Conductor OD2.740 mm | 0.108 in
Nominal Size0.400 in
Outer Conductor OD8.080 mm | 0.318 in
Reel Flangen450.0 mm | 17.7 i
Reel Hub206.0 mm | 8.1 in
Reel Traverse335.0 mm | 13.2 in
Total Weight33.1 kg | 73.0 lb

Electrical Specifications
Cable Impedance50 ohm
Capacitance78 pF/m | 24 pF/ft
dc Resistance, Inner Conductor4.490 ohms/km | 1.370 ohms/kft
dc Resistance, Outer Conductor5.610 ohms/km | 1.710 ohms/kft
dc Test Voltage2500 V
Jacket Spark Test Voltage (rms)8000 V
Maximum Frequency16.20 GHz
Operating Frequency Band30 – 6000 MHz
Peak Power16.0 kW
Shielding Effectiveness>90 dB
Velocity85%

Environmental Specifications
Installation Temperature-40 °C to +85 °C ( -40 °F to +185 °F)
Operating Temperature-40 °C to +85 °C (-40 °F to +185 °F)
Storage Temperature-70 °C to +85 °C (-94 °F to +185 °F)

General Specifications
Cable TypeCNT-400
Braid Coverage86% braid
BrandCinta
Packaging TypeReel

Mechanical Specifications
Bending Moment0.7 N-m | 0.5 ft lb
Flat Plate Crush Strength0.7 kg/mm | 40.0 lb/in
Minimum Bend Radius, Single Bend25.40 mm | 1.00 in
Tensile Strength73 kg | 160 lb

Performance
FrequencyAttenuation (dB/100 m)Attenuation (dB/100 ft)
30 MHz2.490.76
50 MHz3.180.97
150 MHz4.921.50
220 MHz6.231.90
450 MHz8.862.70
900 MHz12.803.90
1500 MHz16.705.10
1800 MHz18.405.60
2000 MHz19.405.90
2400 MHz21.656.60
2500 MHz22.006.70
3000 MHz24.607.50
4000 MHz28.878.80
4500 MHz30.849.40
5000 MHz32.8110.00
5200 MHz33.4610.20
5500 MHz34.7810.60
5800 MHz35.7610.90
6000 MHz36.4211.10

Regulatory Compliance/Certifications
AgencyClassification




Price : Rp 16.000